Flex duct and duct sizing basics
Short answer: size duct for about 400 CFM per ton; typical branch runs are 6 inch (about 100 CFM) and 8 inch (about 200 CFM).
By the HVAC Plus 4U team · Updated November 2026
Rough branch capacities
| 6" flex | about 100 CFM |
|---|---|
| 7" flex | about 140 CFM |
| 8" flex | about 200 CFM |
| 10" flex | about 320 CFM |
| 12" flex | about 500 CFM |
Approximate, for straight, fully stretched runs at typical residential static pressure. A Manual D design gives exact sizes.
Install flex the right way
Pull flex fully tight, keep runs short, support it every 4 to 5 feet with 1.5" strap, and avoid sharp bends. Compressed or sagging flex can lose a third or more of its airflow.
R6 or R8?
R8 is required in some codes for ducts in unconditioned attics and is a good choice in hot climates. R6 is common elsewhere. Check your local code.
Seal every joint
Seal connections with UL 181 foil tape or mastic. Leaky ducts in an attic can waste 20% or more of the air a system moves.