SEER2 explained: efficiency ratings and minimums
Short answer: SEER2 measures cooling efficiency under the DOE test used since 2023; higher is more efficient, and federal minimums depend on region and equipment type.
By the HVAC Plus 4U team · Updated November 2026
SEER vs SEER2
SEER2 uses higher external static pressure in testing, closer to real duct systems, so SEER2 numbers read about 4.5% lower than the old SEER for the same unit.
Federal minimums (split systems)
| Heat pump, all regions | 14.3 SEER2 and 7.5 HSPF2 |
|---|---|
| Air conditioner, North | 13.4 SEER2 |
| Air conditioner, Southeast & Southwest, under 45,000 BTU/h | 14.3 SEER2 |
| Air conditioner, Southeast & Southwest, 45,000 BTU/h and up | 13.8 SEER2 |
What the tiers mean
Single-stage units run at full power or off. Two-stage units run at a low stage most of the time for steadier comfort and better humidity control. Variable-speed units adjust in small steps and have the highest SEER2 ratings.
HSPF2 and AFUE
HSPF2 rates heat pump heating efficiency. AFUE rates gas furnaces: 80% AFUE vents through a metal flue; 90%+ AFUE condensing furnaces vent through PVC.